Specification
Centroller AD11+ Technical Information
- Dialling : Up to 6-telephone number of 2 and 14 digits tone & PABX Dialling.
- Message : Factory set "This auto dialler on (user own tel no) calling (emergency no 1 to 6) there is an emergency please acknowledge. "
- Instant Call : While listening to the emergency message on line, pressing Acknowledge key 1 twice would acknowledge the call & also cease to dial any further. If key # pressed twice, then auto dialler will terminated the current call and will call next person in the memory sequence.
- Attempts : 10 Attempts for each number over an 8 to 9 hour period.
- Detection : Dial tone, busy tone, park tone & answer back tone.
- Telephone Interface : Via flexible cord and plug.
- Trigger Input(s) :
- NCV free contacts
- Alarm mode - When normally closed contacts opens more than 0.5secs. If this input used then 2 AA batteries are required.
- Negative trigger
- Normally high (range 3Vdc - 30Vdc).
- Alarm Mode - When drops down to 0V (maximum 0.3Vdc)
-
Supply : 4.5V (3 x AA batteries) minimum 2-year life.( Mains power version also available. Product code is AD11M+)
- Alarm voltage : 3.0V DC 2 x AA size batteries.
- Power :
- Standby - 0.25mWatts consumption
- When dialling,
programming/recalling numbers - 150mWatts
- Environment : 0 to 40 degree C.
- REN : REN 0.1 (4 additional telephones also with a REN of 1 may be used with the Auto dialler).
- Dimensions : 240 x 160 x 47mm.
- Weight (packed) : 700gms.
|